UH400
FREQUENCY-AGILE
PLUG-ON UHF TRANSMITTER
OPERATING INSTRUCTIONS
and trouble-shooting guide
LECTROSONICS, INC.
Rio Rancho, NM
www.lectrosonics.com
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - LECTROSONICS, INC

UH400 FREQUENCY-AGILE PLUG-ON UHF TRANSMITTER OPERATING INSTRUCTIONS and trouble-shooting guide LECTROSONICS, INC. Rio Rancho, NM www.lectroson

Pagina 2 - TABLE OF CONTENTS

UH400 SPECIFICATIONS AND FEATURES Operating frequencies: 537.600 to 607.900 MHz; 614.100 to 793.500 MHz Frequency selection: 256 frequencies i

Pagina 3 - DIGITAL HYBRID TECHNOLOGY

Frequency Agile Plug-on UHF Transmitter SERVICE AND REPAIR If your system malfunctions, you should attempt to correct or isolate the trouble before c

Pagina 4 - CONTROLS AND FUNCTIONS

LIMITED ONE YEAR WARRANTYThe equipment is warranted for one year from date of purchase against defects in materials or workmanship provided it was pur

Pagina 5 - MODULATION LEDS

UH400 INTRODUCTION Thank you for selecting the Lectrosonics UH400 frequency agile, plug-on transmitter. The UH400 combines over 80 years of engineer

Pagina 6

Frequency Agile Plug-on UHF Transmitter GENERAL TECHNICAL DESCRIPTION GENERAL The 400 system uses 75kHz wide deviation for an extremely high signal t

Pagina 7 - SELECTING THE OPERATING MODE

UH400 NO PRE-EMPHASIS/DE-EMPHASIS The signal to noise ratio of the 400 system is high enough to preclude the need for conventional pre-emphasis (H

Pagina 8 - POLARITY

Frequency Agile Plug-on UHF Transmitter indication immediately after being put in the unit, but will soon discharge to the point where the LED will

Pagina 9 - Rio Rancho, NM – USA

UH400 INPUT LIMITER The 400 series transmitters employ a digitally-controlled analog audio limiter just before the analog-to-digital converter. The

Pagina 10 - SPECIFICATIONS AND FEATURES

Frequency Agile Plug-on UHF Transmitter OPERATING TIPS The MIC LEVEL control knob should not be used to control the volume of your sound system or rec

Pagina 11 - RETURNING UNITS FOR REPAIR

UH400 BATTERY REPLACEMENT The UH400 transmitter is powered by a standard alkaline 9 Volt battery. It is important that you use ONLY ALKALINE OR LITHI

Pagina 12 - September 4, 2003

Frequency Agile Plug-on UHF Transmitter SYMPTOM POSSIBLE CAUSE RECEIVER RF LAMP OFF 1. Transmitter not turned on. 2. Transmitter battery is dead. 3.